								#include "iot_cli.h"
							 | 
						||
| 
								 | 
							
								#include "iot_bt_ext_api.h"
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								static void iot_cli_bt_recv(iot_pkt_t *pkt)
							 | 
						||
| 
								 | 
							
								{
							 | 
						||
| 
								 | 
							
								    iot_cli_pre_handle_data(iot_pkt_data(pkt), iot_pkt_data_len(pkt),
							 | 
						||
| 
								 | 
							
								        COMMUNICATOR_BT);
							 | 
						||
| 
								 | 
							
								    iot_pkt_free(pkt);
							 | 
						||
| 
								 | 
							
								}
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								uint32_t iot_cli_bt_communicator_init()
							 | 
						||
| 
								 | 
							
								{
							 | 
						||
| 
								 | 
							
								    return iot_bt_ext_rpt_register(IOT_BT_EXT_PORT_USER_VIRTUAL_CLI,
							 | 
						||
| 
								 | 
							
								        iot_cli_bt_recv);
							 | 
						||
| 
								 | 
							
								}
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								void iot_cli_bt_communicator_send(iot_pkt_t *pkt)
							 | 
						||
| 
								 | 
							
								{
							 | 
						||
| 
								 | 
							
								    iot_bt_ext_send(IOT_BT_EXT_PORT_USER_VIRTUAL_CLI, pkt);
							 | 
						||
| 
								 | 
							
								}
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								iot_pkt_t* iot_cli_bt_create_cli_msg(uint32_t moduleid, uint32_t msgid,
							 | 
						||
| 
								 | 
							
								    uint8_t *buffer, uint32_t bufferlen, uint16_t sn)
							 | 
						||
| 
								 | 
							
								{
							 | 
						||
| 
								 | 
							
								    iot_pkt_t *data;
							 | 
						||
| 
								 | 
							
								    uint32_t datalen = 0;
							 | 
						||
| 
								 | 
							
								    uint8_t* data_ptr;
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								    data = iot_bt_ext_send_pkt_get(bufferlen + sizeof(cli_msg_hdr_t));
							 | 
						||
| 
								 | 
							
								    if (data == NULL) {
							 | 
						||
| 
								 | 
							
								        return NULL;
							 | 
						||
| 
								 | 
							
								    }
							 | 
						||
| 
								 | 
							
								    data_ptr = iot_pkt_data(data);
							 | 
						||
| 
								 | 
							
								    cli_add_msg_header(buffer, bufferlen, moduleid, msgid, sn,
							 | 
						||
| 
								 | 
							
								        (uint8_t**)&data_ptr, &datalen, NULL);
							 | 
						||
| 
								 | 
							
								    if (iot_pkt_set_tail(data, iot_pkt_data(data) + datalen) == NULL) {
							 | 
						||
| 
								 | 
							
								        iot_pkt_free(data);
							 | 
						||
| 
								 | 
							
								        return NULL;
							 | 
						||
| 
								 | 
							
								    }
							 | 
						||
| 
								 | 
							
								    return data;
							 | 
						||
| 
								 | 
							
								}
							 |