|  | Copyright(c) 2019 by Aerospace C.Power (Chongqing) Microelectronics. ALL RIGHTS RESERVED. | ||
|  | 
 | ||
|  | This Information is proprietary to Aerospace C.Power (Chongqing) Microelectronics and MAY NOT | ||
|  | be copied by any method or incorporated into another program without | ||
|  | the express written consent of Aerospace C.Power. This Information or any portion | ||
|  | thereof remains the property of Aerospace C.Power. The Information contained herein | ||
|  | is believed to be accurate and Aerospace C.Power assumes no responsibility or | ||
|  | liability for its use in any way and conveys no license or title under | ||
|  | any patent or copyright and makes no representation or warranty that this | ||
|  | Information is free from patent or copyright infringement. | ||
|  | 
 | ||
|  | ****************************************************************************/ | ||
|  | 
 | ||
|  | #include "iot_errno.h"
 | ||
|  | #include "iot_io.h"
 | ||
|  | #include "iot_app.h"
 | ||
|  | #include "iot_config.h"
 | ||
|  | #include "iot_system.h"
 | ||
|  | 
 | ||
|  | #include "iot_oem_api.h"
 | ||
|  | #include "iot_board_api.h"
 | ||
|  | 
 | ||
|  | #include "iot_cli_host_interface.h"
 | ||
|  | #include "iot_cli_plc_module.h"
 | ||
|  | #include "iot_cli_plc_tx_rx.h"
 | ||
|  | #include "iot_cli_plc_nw.h"
 | ||
|  | #include "iot_cli_host_upgrade.h"
 | ||
|  | #include "iot_cli_ckb.h"
 | ||
|  | #include "iot_cli_dbg_log.h"
 | ||
|  | #include "iot_cli_ada_dump.h"
 | ||
|  | #include "iot_cli_ul_buf.h"
 | ||
|  | #include "iot_cli_discovery.h"
 | ||
|  | #include "iot_cli_rate_test.h"
 | ||
|  | #include "iot_cli_set_info.h"
 | ||
|  | #include "iot_cli_plc_mgr_alive.h"
 | ||
|  | #include "iot_cli_hw_ver.h"
 | ||
|  | 
 | ||
|  | #if PLC_SUPPORT_CCO_ROLE
 | ||
|  | extern CLI_MSG_ENTRY | ||
|  | all_cli_cco_msg_entry[]; | ||
|  | #endif
 | ||
|  | extern CLI_MSG_ENTRY | ||
|  | all_cli_sta_msg_entry[]; | ||
|  | extern iot_cli_host_info_t *host_info; | ||
|  | extern iot_cli_t cli; | ||
|  | extern uint8_t cli_ftm_mode; | ||
|  | extern uint32_t cli_module_type; | ||
|  | 
 | ||
|  | iot_plc_host_config_t *host_config = NULL; | ||
|  | 
 | ||
|  | #if PLC_COMM_ENABLE
 | ||
|  | static uint8_t iot_cli_register() | ||
|  | { | ||
|  |     iot_plc_app_t host_app; | ||
|  |     host_app.app_id = IOT_PLC_APP_HOST_INTERFACE; | ||
|  |     host_app.param = NULL; | ||
|  |     host_app.prio = 3; | ||
|  |     host_app.recv = iot_cli_plc_recv; | ||
|  | 
 | ||
|  |     host_config->app_handle = iot_plc_register_app(&host_app); | ||
|  |     if (host_config->app_handle == NULL) { | ||
|  |         iot_printf("App handle NULL (%s)\n", __FUNCTION__); | ||
|  |         return ERR_INVAL; | ||
|  |     } | ||
|  |     return ERR_OK; | ||
|  | } | ||
|  | #else
 | ||
|  | static uint8_t iot_cli_register() | ||
|  | { | ||
|  |     host_config->app_handle = NULL; | ||
|  |     return ERR_OK; | ||
|  | } | ||
|  | #endif /* PLC_COMM_ENABLE */
 | ||
|  | 
 | ||
|  | uint8_t iot_cli_module_handle_msg( | ||
|  |     cli_moduleid_t moduleid, uint32_t msgid, iot_cli_msg_t *msg) | ||
|  | { | ||
|  | #if PLC_SUPPORT_CCO_ROLE
 | ||
|  |     if (iot_plc_is_client_mode()) | ||
|  |     { | ||
|  |         if (cli_execute_msg_entry(moduleid, msgid, all_cli_sta_msg_entry, msg)) { | ||
|  |             return 1; | ||
|  |         } | ||
|  |     } else { | ||
|  |         if (cli_execute_msg_entry(moduleid, msgid, all_cli_cco_msg_entry, msg)) { | ||
|  |             return 1; | ||
|  |         } | ||
|  |     } | ||
|  | #else
 | ||
|  |     if (cli_execute_msg_entry(moduleid, msgid, all_cli_sta_msg_entry, msg)) { | ||
|  |         return 1; | ||
|  |     } | ||
|  | #endif
 | ||
|  | 
 | ||
|  |     return 0; | ||
|  | } | ||
|  | 
 | ||
|  | uint8_t iot_cli_module_handle_task_msg(iot_cli_msg_t *cli_msg, uint16_t id) | ||
|  | { | ||
|  |     uint8_t handled = 1; | ||
|  |     switch (id) { | ||
|  |     case IOT_CLI_HOST_MSG: | ||
|  |         cli_handle_plc_msg(cli_msg->data); | ||
|  |         break; | ||
|  |     case IOT_CLI_UPGRADE_TIMER: | ||
|  |         iot_cli_upgrade_handle_timer_msg(); | ||
|  |         break; | ||
|  |     case IOT_CLI_RATE_TEST_TIMER: | ||
|  |         iot_cli_rate_test_handle_timer_msg(); | ||
|  |         break; | ||
|  |     case IOT_CLI_SG_MSG: | ||
|  |         iot_cli_sg_handle_msg(cli_msg->data); | ||
|  |         break; | ||
|  |     case IOT_CLI_SET_TIMER: | ||
|  |         iot_cli_set_info_handle_timer_msg(); | ||
|  |         break; | ||
|  |     case IOT_CLI_QUERY_HW_TIMER: | ||
|  |         iot_cli_query_hw_ver_handle_timer_msg(); | ||
|  |         break; | ||
|  | #if PLC_SUPPORT_CCO_ROLE
 | ||
|  |     case IOT_CLI_RPT_TOPO_TIMER: | ||
|  |         iot_plc_query_nw_topo(host_config->app_handle, | ||
|  |             host_config->cli_request_id, host_config->topo_ver, | ||
|  |             IOT_PLC_QUERY_TOPO_START_AS_TEI, | ||
|  |             host_config->topo_query_start_index, | ||
|  |             host_config->topo_count_in_packet); | ||
|  |         break; | ||
|  |     case IOT_CLI_BCAST_TX_DONE: | ||
|  |         cli_remote_upgrade_bcast_tx_done(); | ||
|  |         break; | ||
|  | #endif
 | ||
|  | #if (IOT_STA_CONTROL_MODE == IOT_STA_CONTROL_TYPE_STA)
 | ||
|  |     case IOT_CLI_ADA_MSG: | ||
|  |         iot_cli_handle_ada_msg(cli_msg->data); | ||
|  |         break; | ||
|  |     case IOT_CLI_DUMP_TIMER: | ||
|  |         iot_cli_ada_dump_handle_timer_msg(); | ||
|  |         break; | ||
|  | #endif
 | ||
|  | #if IOT_TPUT_APP_ENABLE
 | ||
|  |     case IOT_CLI_TPUT_MSG: | ||
|  |         iot_cli_tput_handle_msg(cli_msg->data); | ||
|  |         break; | ||
|  | #endif
 | ||
|  |     default: | ||
|  |         handled = 0; | ||
|  |         break; | ||
|  |     } | ||
|  | 
 | ||
|  |     return handled; | ||
|  | } | ||
|  | 
 | ||
|  | uint8_t iot_cli_module_cancel_task_msg( | ||
|  |     iot_cli_msg_t *cli_msg, uint16_t id) | ||
|  | { | ||
|  |     switch (id) { | ||
|  |     case IOT_CLI_HOST_MSG: | ||
|  |     case IOT_CLI_UPGRADE_TIMER: | ||
|  |     case IOT_CLI_RATE_TEST_TIMER: | ||
|  |     case IOT_CLI_SG_MSG: | ||
|  |     case IOT_CLI_SET_TIMER: | ||
|  |     case IOT_CLI_QUERY_HW_TIMER: | ||
|  |     case IOT_CLI_RPT_TOPO_TIMER: | ||
|  |     case IOT_CLI_BCAST_TX_DONE: | ||
|  | #if IOT_TPUT_APP_ENABLE
 | ||
|  |     case IOT_CLI_TPUT_MSG: | ||
|  | #endif
 | ||
|  | #if (IOT_STA_CONTROL_MODE == IOT_STA_CONTROL_TYPE_STA)
 | ||
|  |     case IOT_CLI_ADA_MSG: | ||
|  |     case IOT_CLI_DUMP_TIMER: | ||
|  | #endif
 | ||
|  |         if (cli_msg->data) { | ||
|  |             iot_pkt_free(cli_msg->data); | ||
|  |         } | ||
|  |         break; | ||
|  |     default: | ||
|  |         break; | ||
|  |     } | ||
|  | 
 | ||
|  |     return 1; | ||
|  | } | ||
|  | 
 | ||
|  | void iot_cli_module_init_uart(commnucator_t * com, uint8_t interface_type) | ||
|  | { | ||
|  |     if (com && (com->is_initiated == 0)) { | ||
|  | #if (HW_PLATFORM != HW_PLATFORM_SIMU) && (!IOT_STA_CONTROL_MODE)
 | ||
|  |         if ((MODULE_TYPE_CCO == cli_module_type) || cli_ftm_mode) { | ||
|  | #endif
 | ||
|  |             com->type = interface_type; | ||
|  |             if (com->type == COMMUNICATOR_UART) | ||
|  |             { | ||
|  |                 os_mem_set(&(com->uart_frame), 0, sizeof(iot_frame_fmt)); | ||
|  |                 com->uart_frame.preamble_codelen = 2; | ||
|  |                 os_mem_cpy(com->uart_frame.preamble_code, "##", 2); | ||
|  |                 com->uart_frame.backcode_len = 2; | ||
|  |                 os_mem_cpy(com->uart_frame.backcode, "@@", 2); | ||
|  |                 com->uart_frame.datalen_offset = 20; | ||
|  |                 com->uart_frame.datalen_size = 4; | ||
|  |                 com->uart_frame.backcode_offset = 0; | ||
|  |                 com->uart_frame.frame_timeout = 200; | ||
|  |             } | ||
|  | #if IOT_STA_CONTROL_MODE > IOT_STA_CONTROL_TYPE_PPM_DETECT
 | ||
|  |             // TODO:  reserved for config depending on GPIO
 | ||
|  |             IOT_ASSERT(0); | ||
|  | #else
 | ||
|  | #if HW_PLATFORM == HW_PLATFORM_SIMU
 | ||
|  |             com->com_num = UART_CLI_PORT; | ||
|  | #else
 | ||
|  |             com->com_num = iot_board_get_uart(UART_CLI_PORT); | ||
|  | #endif
 | ||
|  | #endif
 | ||
|  |             commnunicator_init(com, &cli, CALLER_PLC_CLI, 1); | ||
|  | 
 | ||
|  | #if (HW_PLATFORM != HW_PLATFORM_SIMU) && (!IOT_STA_CONTROL_MODE)
 | ||
|  |         } | ||
|  | #endif
 | ||
|  |         cli.commu.is_initiated = 1; | ||
|  |     } | ||
|  | } | ||
|  | 
 | ||
|  | /* timer for rpt topo data */ | ||
|  | void iot_cli_rpt_topo_data_timer(timer_id_t timer_id, void *arg) | ||
|  | { | ||
|  |     (void)timer_id; | ||
|  |     (void)arg; | ||
|  | 
 | ||
|  |     iot_task_msg_t *msg; | ||
|  |     msg = iot_cli_create_cli_msg(IOT_CLI_RPT_TOPO_TIMER, NULL); | ||
|  | 
 | ||
|  |     if (msg) { | ||
|  |         iot_task_queue_msg(cli.cli_task_h, msg, IOT_CLI_QUEUE_TIMER); | ||
|  |     } | ||
|  | } | ||
|  | 
 | ||
|  | uint8_t iot_cli_proto_module_init() | ||
|  | { | ||
|  |     uint8_t ret = ERR_OK; | ||
|  | 
 | ||
|  |     host_config = (iot_plc_host_config_t*) | ||
|  |         os_mem_malloc(IOT_CLI_MID, sizeof(iot_plc_host_config_t)); | ||
|  |     if (host_config == NULL) { | ||
|  |         ret = ERR_NOMEM; | ||
|  |         goto label_failed1; | ||
|  |     } | ||
|  |     os_mem_set(host_config, 0, sizeof(host_config)); | ||
|  | 
 | ||
|  |     // resiter cli app to plc lib
 | ||
|  |     ret = iot_cli_register(); | ||
|  |     if (ret != ERR_OK) { | ||
|  |         goto label_failed1; | ||
|  |     } | ||
|  | 
 | ||
|  |     host_config->dev_role = IOT_PLC_DEV_ROLE_INVALID; | ||
|  |     host_config->dev_type = IOT_PLC_DEV_TYPE_INVAL; | ||
|  | 
 | ||
|  | #if PLC_SUPPORT_CCO_ROLE
 | ||
|  |     host_config->topo_data_timer = os_create_timer(IOT_CLI_MID, 0, | ||
|  |         iot_cli_rpt_topo_data_timer, NULL); | ||
|  |     iot_cli_ckb_init(); | ||
|  | #endif
 | ||
|  | 
 | ||
|  | #if IOT_CLI_CKB_ADDR_MAPPING
 | ||
|  |     iot_cli_addr_mapping_init(); | ||
|  | #endif /* IOT_CLI_CKB_ADDR_MAPPING */
 | ||
|  | 
 | ||
|  | #if (PLC_SUPPORT_CCO_ROLE || (IOT_STA_CONTROL_MODE == IOT_STA_CONTROL_TYPE_STA))
 | ||
|  |     iot_cli_plc_mgr_alive_init(); | ||
|  | #endif
 | ||
|  |     iot_cli_rate_test_init(); | ||
|  |     iot_cli_set_info_init(); | ||
|  |     iot_cli_dbg_log_init(); | ||
|  |     iot_cli_query_hw_ver_init(); | ||
|  | #if (IOT_STA_CONTROL_MODE == IOT_STA_CONTROL_TYPE_STA)
 | ||
|  |     iot_cli_ada_dump_init(); | ||
|  | #endif
 | ||
|  | #if PLC_SUPPORT_CCO_ROLE
 | ||
|  |     iot_cli_ul_buf_init(); | ||
|  | #endif
 | ||
|  | 
 | ||
|  | #if (IOT_STA_CONTROL_MODE == IOT_STA_CONTROL_TYPE_STA)
 | ||
|  |     iot_cli_host_set_ckb_dev_type(); | ||
|  |     iot_plc_wdg_set(host_config->app_handle, 0, 0); | ||
|  |     iot_plc_set_whitelist(host_config->app_handle, | ||
|  |         IOT_PLC_API_REQ_ID_DEFAULT, IOT_PLC_WL_ENABLE, 0, NULL); | ||
|  |     cli_discovery_init(); | ||
|  | #endif
 | ||
|  |     return ERR_OK; | ||
|  | label_failed1: | ||
|  |     iot_cli_proto_module_deinit(); | ||
|  |     return ret; | ||
|  | } | ||
|  | 
 | ||
|  | void iot_cli_proto_module_deinit() | ||
|  | { | ||
|  | #if PLC_SUPPORT_CCO_ROLE
 | ||
|  |     iot_cli_ckb_deinit(); | ||
|  | #endif /* PLC_SUPPORT_CCO_ROLE */
 | ||
|  | #if IOT_CLI_CKB_ADDR_MAPPING
 | ||
|  |     iot_cli_addr_mapping_deinit(); | ||
|  | #endif /* IOT_CLI_CKB_ADDR_MAPPING */
 | ||
|  |     iot_cli_rate_test_deinit(); | ||
|  | #if (IOT_STA_CONTROL_MODE == IOT_STA_CONTROL_TYPE_STA)
 | ||
|  |     cli_discovery_deinit(); | ||
|  | #endif
 | ||
|  |     if (host_config) { | ||
|  |         os_mem_free(host_config); | ||
|  |         host_config = NULL; | ||
|  |     } | ||
|  | } |