|  | Copyright(c) 2019 by Aerospace C.Power (Chongqing) Microelectronics. ALL RIGHTS RESERVED. | ||
|  | 
 | ||
|  | This Information is proprietary to Aerospace C.Power (Chongqing) Microelectronics and MAY NOT | ||
|  | be copied by any method or incorporated into another program without | ||
|  | the express written consent of Aerospace C.Power. This Information or any portion | ||
|  | thereof remains the property of Aerospace C.Power. The Information contained herein | ||
|  | is believed to be accurate and Aerospace C.Power assumes no responsibility or | ||
|  | liability for its use in any way and conveys no license or title under | ||
|  | any patent or copyright and makes no representation or warranty that this | ||
|  | Information is free from patent or copyright infringement. | ||
|  | 
 | ||
|  | ****************************************************************************/ | ||
|  | 
 | ||
|  | #include "os_utils_api.h"
 | ||
|  | 
 | ||
|  | #include "iot_board.h"
 | ||
|  | #include "iot_io_api.h"
 | ||
|  | #include "iot_upgrade_api.h"
 | ||
|  | 
 | ||
|  | #include "iot_cli.h"
 | ||
|  | #include "iot_cli_host_interface.h"
 | ||
|  | #include "iot_cli_plc_module.h"
 | ||
|  | #include "iot_cli_common.h"
 | ||
|  | #include "iot_cli_plc_tx_rx.h"
 | ||
|  | #include "iot_cli_set_info.h"
 | ||
|  | 
 | ||
|  | extern iot_plc_host_config_t *host_config; | ||
|  | extern iot_cli_t cli; | ||
|  | 
 | ||
|  | timer_id_t set_info_timer; | ||
|  | uint8_t    set_id; | ||
|  | 
 | ||
|  | #if (IOT_STA_CONTROL_MODE == IOT_STA_CONTROL_TYPE_STA)
 | ||
|  | static void cli_set_vendor_local_ack(uint8_t *src_mac) | ||
|  | { | ||
|  |     cli_vendor_report report; | ||
|  |     report.set_id = set_id; | ||
|  |     iot_mac_addr_cpy(report.dst, host_config->mac_addr); | ||
|  |     iot_cli_send_to_host(CLI_MSGID_SET_VENDOR_ACK, | ||
|  |         (uint8_t*)&report, sizeof(cli_vendor_report), src_mac); | ||
|  | } | ||
|  | #endif
 | ||
|  | 
 | ||
|  | /* cli set vendor handler */ | ||
|  | void cli_set_vendor( | ||
|  |     uint8_t *buffer, uint32_t bufferlen, uint8_t *src_mac) | ||
|  | { | ||
|  |     (void)src_mac; | ||
|  |     cli_vendor_info *vendor_info = | ||
|  |         (cli_vendor_info *)buffer; | ||
|  | 
 | ||
|  |     if ((!vendor_info) || (bufferlen < sizeof(*vendor_info))) { | ||
|  |         iot_printf("dev save vendor, invalid para\n"); | ||
|  |         return; | ||
|  |     } | ||
|  | 
 | ||
|  |     if (host_config->dev_role != IOT_PLC_DEV_ROLE_CCO) { | ||
|  | 
 | ||
|  |         if (set_id != vendor_info->set_id) | ||
|  |         { | ||
|  |             iot_printf("sta set vendor %lu %lu\n", | ||
|  |                 set_id, vendor_info->set_id); | ||
|  |             iot_board_save_user_vendor_id(vendor_info->vendor); | ||
|  |             set_id = vendor_info->set_id; | ||
|  |         } else { | ||
|  |             iot_printf("sta vendor already set\n"); | ||
|  |         } | ||
|  | 
 | ||
|  | #if (IOT_STA_CONTROL_MODE == IOT_STA_CONTROL_TYPE_STA)
 | ||
|  |         cli_set_vendor_local_ack(src_mac); | ||
|  | #else
 | ||
|  |         if (!os_is_timer_active(set_info_timer) && | ||
|  |             vendor_info->control) { | ||
|  |             if (vendor_info->report_window > | ||
|  |                 CLI_SET_VENDOR_TIME_WINDOW) { | ||
|  |                 vendor_info->report_window = | ||
|  |                     CLI_SET_VENDOR_TIME_WINDOW; | ||
|  |             } | ||
|  |             os_start_timer(set_info_timer, | ||
|  |                 os_rand() % vendor_info->report_window); | ||
|  |         } | ||
|  | #endif
 | ||
|  |     } | ||
|  | #if PLC_SUPPORT_CCO_ROLE
 | ||
|  |     else { | ||
|  |         cli_set_vendor_ack ack; | ||
|  | 
 | ||
|  |         ack.result = 0; | ||
|  |         iot_cli_send_to_host(CLI_MSGID_SET_VENDOR_ACK, | ||
|  |             (uint8_t *)&ack, sizeof(ack), src_mac); | ||
|  | 
 | ||
|  |         if (iot_mac_addr_cmp(host_config->mac_addr, vendor_info->dst)) | ||
|  |         { | ||
|  |             // set cco
 | ||
|  |             if (set_id != vendor_info->set_id) { | ||
|  |                 iot_printf("cco set vendor %lu %lu\n", | ||
|  |                     set_id, vendor_info->set_id); | ||
|  |                 iot_board_save_user_vendor_id(vendor_info->vendor); | ||
|  |                 set_id = vendor_info->set_id; | ||
|  |             } else { | ||
|  |                 iot_printf("cco vendor already set\n"); | ||
|  |             } | ||
|  |         } else { | ||
|  |             // set sta
 | ||
|  |             uint8_t send_type = IOT_PLC_MSG_TYPE_UNICAST; | ||
|  | 
 | ||
|  |             // store requet id for vendor report
 | ||
|  |             host_config->cli_request_id = | ||
|  |                 add_addr_to_mapping_table(src_mac); | ||
|  | 
 | ||
|  |             // check if broadcast
 | ||
|  |             if (iot_mac_is_bcast(vendor_info->dst)) { | ||
|  |                 send_type = IOT_PLC_MSG_TYPE_BCAST; | ||
|  |             } | ||
|  | 
 | ||
|  |             iot_printf("cco forward set cmd stype %lu\n", send_type); | ||
|  |             iot_cli_host_send_data_plc( | ||
|  |                 send_type, CLI_MSGID_SET_VENDOR, | ||
|  |                 vendor_info->dst, buffer, bufferlen); | ||
|  |         } | ||
|  |     } | ||
|  | #endif
 | ||
|  | } | ||
|  | 
 | ||
|  | /* dev save build info func */ | ||
|  | static void cli_dev_save_build_info(cli_build_info *build_info) | ||
|  | { | ||
|  |     iot_build_info_t iot_build_info; | ||
|  | 
 | ||
|  |     if (!build_info) { | ||
|  |         iot_printf("dev save build info, invalid para\n"); | ||
|  |         return; | ||
|  |     } | ||
|  | 
 | ||
|  |     iot_build_info.sw_ver = build_info->sw_ver; | ||
|  |     iot_build_info.year = build_info->year; | ||
|  |     iot_build_info.month = build_info->month; | ||
|  |     iot_build_info.day = build_info->day; | ||
|  |     iot_build_info.hour = build_info->hour; | ||
|  |     iot_build_info.min = build_info->min; | ||
|  |     iot_build_info.sec = build_info->sec; | ||
|  |     iot_board_save_user_build_info(&iot_build_info); | ||
|  | } | ||
|  | 
 | ||
|  | /* cli set build info handler */ | ||
|  | void cli_set_build_info( | ||
|  |     uint8_t *buffer, uint32_t bufferlen, uint8_t *src_mac) | ||
|  | { | ||
|  |     (void)src_mac; | ||
|  |     cli_build_info *build_info = | ||
|  |         (cli_build_info *)buffer; | ||
|  | 
 | ||
|  |     if ((!build_info) || (bufferlen < sizeof(*build_info))) { | ||
|  |         return; | ||
|  |     } | ||
|  | 
 | ||
|  |     if (host_config->dev_role != IOT_PLC_DEV_ROLE_CCO) { | ||
|  | 
 | ||
|  |         if (set_id != build_info->set_id) | ||
|  |         { | ||
|  |             iot_printf("sta set build info %lu %lu %lu\n", | ||
|  |                 set_id, build_info->set_id, build_info->sw_ver); | ||
|  |             cli_dev_save_build_info(build_info); | ||
|  |             set_id = build_info->set_id; | ||
|  |         } else { | ||
|  |             iot_printf("sta build info already set\n"); | ||
|  |         } | ||
|  | 
 | ||
|  |         if (!os_is_timer_active(set_info_timer) && | ||
|  |             build_info->control) { | ||
|  |             if (build_info->report_window > | ||
|  |                 CLI_SET_VENDOR_TIME_WINDOW) { | ||
|  |                 build_info->report_window = | ||
|  |                     CLI_SET_VENDOR_TIME_WINDOW; | ||
|  |             } | ||
|  |             os_start_timer( | ||
|  |                 set_info_timer, | ||
|  |                 os_rand() % build_info->report_window); | ||
|  |         } | ||
|  |     } | ||
|  | #if PLC_SUPPORT_CCO_ROLE
 | ||
|  |     else { | ||
|  |         cli_set_build_info_ack ack; | ||
|  | 
 | ||
|  |         ack.result = 0; | ||
|  |         iot_cli_send_to_host(CLI_MSGID_SET_BUILD_INFO_ACK, | ||
|  |             (uint8_t *)&ack, sizeof(ack), src_mac); | ||
|  | 
 | ||
|  |         if (iot_mac_addr_cmp(host_config->mac_addr, build_info->dst)) | ||
|  |         { | ||
|  |             // set cco
 | ||
|  |             if (set_id != build_info->set_id) { | ||
|  |                 iot_printf("cco set build info %lu %lu\n", | ||
|  |                     set_id, build_info->set_id); | ||
|  |                 cli_dev_save_build_info(build_info); | ||
|  |                 set_id = build_info->set_id; | ||
|  |             } else { | ||
|  |                 iot_printf("cco build info already set\n"); | ||
|  |             } | ||
|  |         } | ||
|  |         else { | ||
|  |             // set sta
 | ||
|  |             uint8_t send_type = IOT_PLC_MSG_TYPE_UNICAST; | ||
|  | 
 | ||
|  |             // store requet id for vendor report
 | ||
|  |             host_config->cli_request_id = add_addr_to_mapping_table(src_mac); | ||
|  | 
 | ||
|  |             // check if broadcast
 | ||
|  |             if (iot_mac_is_bcast(build_info->dst)) { | ||
|  |                 send_type = IOT_PLC_MSG_TYPE_BCAST; | ||
|  |             } | ||
|  | 
 | ||
|  |             iot_printf("cco forward set cmd stype %lu\n", send_type); | ||
|  | 
 | ||
|  |             iot_cli_host_send_data_plc(send_type, CLI_MSGID_SET_BUILD_INFO, | ||
|  |                 build_info->dst, buffer, bufferlen); | ||
|  |         } | ||
|  |     } | ||
|  | #endif
 | ||
|  | } | ||
|  | 
 | ||
|  | #if PLC_SUPPORT_CCO_ROLE
 | ||
|  | /* cco handle venfor report from sta */ | ||
|  | void cli_set_vendor_report( | ||
|  |     uint8_t *buffer, uint32_t bufferlen, uint8_t *src_mac) | ||
|  | { | ||
|  |     (void)src_mac; | ||
|  |     uint8_t *addr = | ||
|  |         get_addr_from_mapping_table(host_config->cli_request_id); | ||
|  | 
 | ||
|  |     iot_cli_send_to_host(CLI_MSGID_VENDOR_REPORT, | ||
|  |         buffer, bufferlen, addr); | ||
|  | } | ||
|  | 
 | ||
|  | /* cco handle build info from sta */ | ||
|  | void cli_set_build_info_report( | ||
|  |     uint8_t *buffer, uint32_t bufferlen, uint8_t *src_mac) | ||
|  | { | ||
|  |     (void)src_mac; | ||
|  |     uint8_t *addr = | ||
|  |         get_addr_from_mapping_table(host_config->cli_request_id); | ||
|  | 
 | ||
|  |     iot_cli_send_to_host(CLI_MSGID_BUILD_INFO_REPORT, | ||
|  |         buffer, bufferlen, addr); | ||
|  | } | ||
|  | #endif
 | ||
|  | 
 | ||
|  | /* timer for set info */ | ||
|  | static void iot_cli_set_info_timer(timer_id_t timer_id, void *arg) | ||
|  | { | ||
|  |     (void)timer_id; | ||
|  |     (void)arg; | ||
|  | 
 | ||
|  |     iot_task_msg_t *msg; | ||
|  |     msg = iot_cli_create_cli_msg(IOT_CLI_SET_TIMER, NULL); | ||
|  | 
 | ||
|  |     if (msg) { | ||
|  |         iot_task_queue_msg(cli.cli_task_h, msg, IOT_CLI_QUEUE_TIMER); | ||
|  |     } | ||
|  | } | ||
|  | 
 | ||
|  | /* check if set venfor */ | ||
|  | static uint8_t iot_cli_is_set_vendor() | ||
|  | { | ||
|  |     if (set_id <= CLI_SET_VENDOR_ID_MAX) | ||
|  |     { | ||
|  |         return 1; | ||
|  |     } | ||
|  | 
 | ||
|  |     return 0; | ||
|  | } | ||
|  | 
 | ||
|  | static void iot_cli_info_reset_report() | ||
|  | { | ||
|  |     if (iot_cli_is_set_vendor()) { | ||
|  |         cli_vendor_report report; | ||
|  |         report.set_id = set_id; | ||
|  |         iot_mac_addr_cpy(report.dst, host_config->mac_addr); | ||
|  |         iot_cli_host_send_data_plc(IOT_PLC_MSG_TYPE_UNICAST, | ||
|  |             CLI_MSGID_VENDOR_REPORT, host_config->cco_mac, | ||
|  |             (uint8_t*)&report, sizeof(cli_vendor_report)); | ||
|  |     } else { | ||
|  |         cli_build_info_report report; | ||
|  |         report.set_id = set_id; | ||
|  |         iot_mac_addr_cpy(report.dst, host_config->mac_addr); | ||
|  |         iot_cli_host_send_data_plc(IOT_PLC_MSG_TYPE_UNICAST, | ||
|  |             CLI_MSGID_BUILD_INFO_REPORT, host_config->cco_mac, | ||
|  |             (uint8_t*)&report, sizeof(cli_build_info_report)); | ||
|  |     } | ||
|  | } | ||
|  | 
 | ||
|  | /* handle set timer msg */ | ||
|  | void iot_cli_set_info_handle_timer_msg() | ||
|  | { | ||
|  |     iot_cli_info_reset_report(); | ||
|  |     // stop timer
 | ||
|  |     os_stop_timer(set_info_timer); | ||
|  | } | ||
|  | 
 | ||
|  | /* init cli set info */ | ||
|  | void iot_cli_set_info_init() | ||
|  | { | ||
|  |     set_id = 0; | ||
|  |     if (host_config->dev_role != IOT_PLC_DEV_ROLE_CCO) | ||
|  |     { | ||
|  |         set_info_timer = os_create_timer(IOT_CLI_MID, 1, | ||
|  |             iot_cli_set_info_timer, NULL); | ||
|  |     } | ||
|  | } | ||
|  | 
 | ||
|  | /* sta handle leave when ver change */ | ||
|  | void iot_cli_user_ver_change_reset() | ||
|  | { | ||
|  |     if (set_id > 0) { | ||
|  |         iot_upgrade_reset(); | ||
|  |     } | ||
|  | } |