468 lines
17 KiB
C
Executable File
468 lines
17 KiB
C
Executable File
/****************************************************************************
|
|
|
|
Copyright(c) 2019 by Aerospace C.Power (Chongqing) Microelectronics. ALL RIGHTS RESERVED.
|
|
|
|
This Information is proprietary to Aerospace C.Power (Chongqing) Microelectronics and MAY NOT
|
|
be copied by any method or incorporated into another program without
|
|
the express written consent of Aerospace C.Power. This Information or any portion
|
|
thereof remains the property of Aerospace C.Power. The Information contained herein
|
|
is believed to be accurate and Aerospace C.Power assumes no responsibility or
|
|
liability for its use in any way and conveys no license or title under
|
|
any patent or copyright and makes no representation or warranty that this
|
|
Information is free from patent or copyright infringement.
|
|
|
|
****************************************************************************/
|
|
#ifndef IOT_BRM_H
|
|
#define IOT_BRM_H
|
|
|
|
/* os shim includes */
|
|
#include "os_types_api.h"
|
|
#include "os_timer_api.h"
|
|
|
|
/* common includes */
|
|
#include "iot_plc_api.h"
|
|
#include "iot_mem_pool_api.h"
|
|
#include "iot_queue_api.h"
|
|
#include "iot_utils_api.h"
|
|
#include "iot_task_api.h"
|
|
#include "iot_uart_api.h"
|
|
#include "iot_plc_pm_api.h"
|
|
#include "iot_addr_hash_table_api.h"
|
|
#include "iot_rtc_api.h"
|
|
|
|
/* protocol header file */
|
|
#include "proto_645.h"
|
|
#include "proto_69845.h"
|
|
#include "proto_gw_app.h"
|
|
#include "iot_brm_common.h"
|
|
#include "iot_brm_nv.h"
|
|
#include "iot_brm_cache.h"
|
|
#include "iot_brm_rec.h"
|
|
|
|
#if IOT_BRM_DEVADP_ENABLE
|
|
#include "iot_brm_adp.h"
|
|
#include "iot_brm_proto_devadp_645_ext.h"
|
|
#endif
|
|
|
|
#ifdef __cplusplus
|
|
extern "C" {
|
|
#endif
|
|
|
|
#if (IOT_BRM_ENABLE)
|
|
|
|
/* define node listed node hash table size */
|
|
#define IOT_BRM_NODE_HASH_TABLE_SIZE 4
|
|
|
|
/* define the maximum number of reading task supported */
|
|
#define IOT_BRM_SUPPORT_MR_TASK_NUM 4
|
|
/* maximum number of data items supported per read task */
|
|
#define IOT_BRM_MR_TASK_SUPPORT_DI_MAX 10
|
|
/* Define the default maximum number of reading times for reading task */
|
|
#define IOT_BRM_MR_TASK_SEND_MAX_DEFAULT 2
|
|
/* update htm info interval time, unit is 1s */
|
|
#define IOT_BRM_HTM_TIME_INTERVAL (60)
|
|
/* debug fastly get htm info delay, unit is 1s */
|
|
#define IOT_BRM_HTM_TIME_INTERVAL_FAST (1)
|
|
|
|
/* define the status of the read task */
|
|
#define IOT_BRM_MR_TASK_STATE_IDLE 0 /* idle state, can be started */
|
|
#define IOT_BRM_MR_TASK_STATE_READY 1 /* ready state, to be executed */
|
|
#define IOT_BRM_MR_TASK_STATE_EXE 2 /* execution state, exit at done */
|
|
|
|
/* define the command reason for the read task */
|
|
#define IOT_BRM_MR_TASK_CMD_REASON_STARTUP 0
|
|
#define IOT_BRM_MR_TASK_CMD_REASON_UPGRADE 1
|
|
|
|
/* define 485 management status */
|
|
#define IOT_BRM_RS485_STATE_IDLE 0
|
|
#define IOT_BRM_RS485_STATE_READY 1
|
|
#define IOT_BRM_RS485_STATE_FWD 2
|
|
#define IOT_BRM_RS485_STATE_MR 3
|
|
#define IOT_BRM_RS485_STATE_CHECK 4
|
|
#define IOT_BRM_RS485_STATE_FWD_MODBUS 5
|
|
#define IOT_BRM_RS485_STATE_CORR_TIME 6
|
|
#define IOT_BRM_RS485_STATE_SLAVE_MODE 7
|
|
|
|
/* defines the load record type of the node */
|
|
#define IOT_BRM_NODE_LR_REC_TYPE_UNKNOWN 0
|
|
#define IOT_BRM_NODE_LR_REC_TYPE_V0 1
|
|
#define IOT_BRM_NODE_LR_REC_TYPE_V1 2
|
|
#define IOT_BRM_NODE_LR_REC_TYPE_NOSUPP 3
|
|
|
|
/* define types of curve reading results */
|
|
#define IOT_BRM_NODE_LR_REC_RES_UNKNOWN 0
|
|
#define IOT_BRM_NODE_LR_REC_RES_NORMAL 1
|
|
#define IOT_BRM_NODE_LR_REC_RES_ABRNORMAL 2
|
|
|
|
/* meter reading task node descriptor */
|
|
typedef struct _iot_brm_mr_task_node {
|
|
/* pointer to node descriptor */
|
|
void *node_desc;
|
|
/* read task node queue link */
|
|
iot_list_head_t link;
|
|
/* remaining send nud per data item */
|
|
uint8_t di_resend[IOT_BRM_MR_TASK_SUPPORT_DI_MAX];
|
|
/* data item bitmap currently being read */
|
|
uint16_t di_bm_cur;
|
|
/* current data item bitmap to be being read */
|
|
uint16_t di_bm;
|
|
} iot_brm_mr_task_node_t;
|
|
|
|
/* branch management node descriptor */
|
|
typedef struct _iot_brm_node_desc {
|
|
/* hash table entry */
|
|
iot_addr_hash_entry_t entry;
|
|
/* proto type, see IOT_BRM_PROTO_TYPE_XXXX */
|
|
uint8_t proto_type;
|
|
/* node index */
|
|
uint8_t idx;
|
|
/* node port, see IOT_BRM_PORT_XXX */
|
|
uint8_t port;
|
|
/* voltage transformer ratio of node, uint is x1 */
|
|
uint8_t v_ratio;
|
|
/* current transformer ratio of node, uint is x1 */
|
|
uint16_t i_ratio;
|
|
/* baud rate, this field is valid only if the node is 485 */
|
|
uint32_t baud;
|
|
/* creator of node, see IOT_BRM_OPERATOR_XXX */
|
|
uint8_t creator : 2,
|
|
/* flag to mark if node time abnormal */
|
|
time_abnormal : 1,
|
|
/* flag to mark if lr rec reading abnormal */
|
|
lr_rec_mr_result : 2,
|
|
/* PPM ping node state, see IOT_BRM_PPM_PING_NODE_STATE_XXX */
|
|
ppm_node_sate : 3;
|
|
uint8_t lr_rec_type;
|
|
/* load record type bitmap to be detected */
|
|
uint8_t lr_rec_detect_bm;
|
|
/* detecting counter before determined lr type:
|
|
* detect_cnt[0] is IOT_BRM_DI_DESC_TYPE_LR_REC_645_V0 deny count;
|
|
* detect_cnt[1] is IOT_BRM_DI_DESC_TYPE_LR_REC_645_V1 deny count;
|
|
* detect_cnt[2] is IOT_BRM_DI_DESC_TYPE_NOR accept count;
|
|
*/
|
|
uint8_t detect_cnt[3];
|
|
/* load record reading error countrer */
|
|
uint8_t lr_rec_abnormal_cnt;
|
|
/* assembly number */
|
|
uint8_t ass_pos : 6,
|
|
/* reserved for further use */
|
|
rsvd1 : 2;
|
|
/* current transmission PPM fix value */
|
|
int8_t ppm_fix;
|
|
/* ppm fix value valid time stamp, uint is 1s */
|
|
uint32_t ppm_valid_ts;
|
|
/* read task node queue links */
|
|
iot_brm_mr_task_node_t mr_task_node[IOT_BRM_SUPPORT_MR_TASK_NUM];
|
|
/* node sampling data set */
|
|
iot_brm_node_samp_t samp;
|
|
/* samp curve buffer */
|
|
iot_brm_cache_cr_t cr;
|
|
} iot_brm_node_desc_t;
|
|
|
|
/* node list descriptor */
|
|
typedef struct _iot_brm_node_list {
|
|
/* meter info hash table */
|
|
iot_addr_hash_table_h node_table;
|
|
/* pointer to the node info in the hash meter*/
|
|
iot_brm_node_desc_t *entry[IOT_BRM_SUPPORT_NODE_MAX];
|
|
/* node cnt */
|
|
uint8_t node_cnt;
|
|
} iot_brm_node_list_t;
|
|
|
|
/* meter reading statistical info descriptor */
|
|
typedef struct {
|
|
/* total reading counter */
|
|
uint8_t total_cnt;
|
|
/* successful reading counter */
|
|
uint8_t sus_cnt;
|
|
} iot_brm_mr_stat_t;
|
|
|
|
/* define the callback function of reading task completion analysis */
|
|
typedef void (*iot_brm_mr_task_done_analysis_func_t)(void *arg);
|
|
|
|
/* this callback function allows each node to configure different data items */
|
|
typedef void (*iot_brm_mr_task_node_cfg_func_t)(void *task,
|
|
iot_brm_node_desc_t *node);
|
|
|
|
/* define data item type */
|
|
#define IOT_BRM_DI_DESC_TYPE_NOR 0
|
|
#define IOT_BRM_DI_DESC_TYPE_LR_REC_645_V0 1
|
|
#define IOT_BRM_DI_DESC_TYPE_LR_REC_645_V1 2
|
|
#define IOT_BRM_DI_DESC_TYPE_LR_REC_OOP 3
|
|
|
|
/* data item description structure */
|
|
typedef struct {
|
|
/* data item magic */
|
|
uint32_t di_magic;
|
|
/* data item type, see IOT_BRM_DI_DESC_TYPE_XXX */
|
|
uint8_t type;
|
|
/* pointer to record column selection data item table */
|
|
uint32_t *csd_magic_tab;
|
|
} di_desc_t;
|
|
|
|
/* meter read task configuration structure definition */
|
|
typedef struct {
|
|
/* the data item descriptor table for dl/t 645 */
|
|
di_desc_t di_645[IOT_BRM_MR_TASK_SUPPORT_DI_MAX];
|
|
/* the data item descriptor table for oop */
|
|
di_desc_t di_oop[IOT_BRM_MR_TASK_SUPPORT_DI_MAX];
|
|
/* if set, the task runs automatically according to the start
|
|
* time and interval.
|
|
*/
|
|
uint32_t auto_start :1,
|
|
/* reserved for further use */
|
|
rsvd :31;
|
|
/* collection interval, uint is 1s. when all nodes are on port 485,
|
|
* this read interval is used.
|
|
*/
|
|
uint32_t interval1;
|
|
/* collection interval, uint is 1s */
|
|
uint32_t interval2;
|
|
/* task run timeout, uins is 1s */
|
|
uint32_t timeout;
|
|
/* task start reference time */
|
|
iot_time_tm_t start_time;
|
|
/* maximum number of retries per data item for 485 port */
|
|
uint8_t send_max_rs485;
|
|
/* maximum number of retries per data item for PLC port */
|
|
uint8_t send_max_plc;
|
|
/* random additional maximum value of start-up reference time,
|
|
* uint is min.
|
|
*/
|
|
uint8_t start_dly_max;
|
|
} iot_brm_mr_task_cfg_t;
|
|
|
|
/* meter reading task descriptor */
|
|
typedef struct _iot_brm_mr_task_t {
|
|
/* task status, see IOT_BRM_MR_TASK_STATE_XXX */
|
|
uint8_t state;
|
|
/* the returned customer ID is registered with the meter reading buffer */
|
|
uint8_t cus_id;
|
|
/* flag mark to if the task is already active */
|
|
uint8_t active :1,
|
|
/* flag mark to if it is necessary to recalculate the reading time */
|
|
reload_req :1,
|
|
/* reserved for further use */
|
|
rsvd :6;
|
|
/* bitmap of the reason for the request to disable the task */
|
|
uint8_t dis_req_reason_bm;
|
|
/* node index bitmap to be collected */
|
|
uint32_t node_bm;
|
|
/* queue of nodes to be read */
|
|
iot_list_head_t node_queue;
|
|
/* queue of nodes to be read */
|
|
iot_list_head_t node_queue_485;
|
|
/* start timestamp - boot time, uint is 1ms */
|
|
uint32_t start_ts;
|
|
/* time when the task was last started -- RTC */
|
|
uint32_t last_start_tm;
|
|
/* time when the task was next started -- RTC */
|
|
uint32_t next_start_tm;
|
|
/* time cost of task, uint is 1ms */
|
|
uint32_t cons;
|
|
/* the time-out for the task to run in one round, uint is 1s */
|
|
uint32_t timeout;
|
|
/* start-up reference time */
|
|
uint32_t start_tm;
|
|
/* collection interval, uint is 1s */
|
|
uint32_t interval;
|
|
/* the cumulative duration of the task run, uint is 1s */
|
|
uint32_t run_dur;
|
|
/* number of 485 nodes to be read */
|
|
uint8_t rs485_node_cnt;
|
|
/* number of plc nodes to be read */
|
|
uint8_t plc_node_cnt;
|
|
/* meter reading statistics for task */
|
|
iot_brm_mr_stat_t stat;
|
|
/* callback function for node collection information configuration */
|
|
iot_brm_mr_task_node_cfg_func_t node_cfg;
|
|
/* analysis callback function of reading task done */
|
|
iot_brm_mr_task_done_analysis_func_t done_analysis_func;
|
|
/* pointer to meter reading task config structure */
|
|
const iot_brm_mr_task_cfg_t *cfg;
|
|
} iot_brm_mr_task_t;
|
|
|
|
/* config info descriptor */
|
|
typedef struct _iot_brm_config_info {
|
|
/* address, little endian */
|
|
uint8_t addr[IOT_MAC_ADDR_LEN];
|
|
/* tsfm address, little-endian */
|
|
uint8_t tsfm_addr[IOT_MAC_ADDR_LEN];
|
|
/* longitude */
|
|
iot_brm_location_unit_t longitude;
|
|
/* latitude */
|
|
iot_brm_location_unit_t latitude;
|
|
/* start time of curve recording */
|
|
uint32_t cr_start;
|
|
/* curve recording interval, uins is 1s */
|
|
uint16_t cr_interval;
|
|
/* TODO: adding more configuration info */
|
|
} iot_brm_config_info_t;
|
|
|
|
/* plc link state info */
|
|
typedef struct _iot_brm_plc_state {
|
|
/* plc app register status. 1 means registered */
|
|
uint8_t app_reg : 1,
|
|
/* plc link status */
|
|
link_ready : 1,
|
|
/* conn less status */
|
|
conn_less_ready : 1,
|
|
/* reserved for further use */
|
|
rsvd : 5;
|
|
/* device ID */
|
|
uint8_t dev_id[IOT_MAC_ADDR_LEN];
|
|
/* reset counter */
|
|
uint16_t reset_cnt;
|
|
/* plc mac address */
|
|
uint8_t addr[IOT_MAC_ADDR_LEN];
|
|
/* cco mac address */
|
|
uint8_t cco_addr[IOT_MAC_ADDR_LEN];
|
|
/* tei of the device */
|
|
uint16_t dev_tei;
|
|
} iot_brm_plc_state_t;
|
|
|
|
/* 485 configuration descriptor*/
|
|
typedef struct _iot_brm_rs485_config {
|
|
/** baud rate */
|
|
uint32_t baud;
|
|
/* threshold for receive timeout. */
|
|
uint32_t thd_rx_tm;
|
|
/** parity. see IOT_UART_PARITY_XXX */
|
|
uint8_t parity;
|
|
/** length of data. see IOT_UART_DLEN_X_BITS */
|
|
uint8_t data;
|
|
/** stop bit. see IOT_UART_STOP_XX_BITS */
|
|
uint8_t stop;
|
|
/** stands for if 'fmt' valid. 1 : valid, 0 : invalid. */
|
|
uint8_t fmt_valid;
|
|
/** the format structure of the frame */
|
|
iot_frame_fmt fmt;
|
|
} iot_brm_rs485_config_t;
|
|
|
|
/* 485 control block descriptor */
|
|
typedef struct _iot_brm_rs485_cb {
|
|
/* state, see IOT_BRM_RS485_STATE_XXX */
|
|
uint8_t state;
|
|
/* pending iot_pkt */
|
|
iot_pkt_t *pend_pkt;
|
|
/* who pend iot_pkt, see iot_brm_data_owner_t */
|
|
iot_brm_data_owner_t pend_from;
|
|
/* 485 uart handle*/
|
|
iot_uart_h handle;
|
|
/* 485 management timer */
|
|
timer_id_t man_timer;
|
|
/* config info form sg app */
|
|
iot_brm_rs485_config_t ext_config;
|
|
/* cache last send data */
|
|
uint8_t last_send_data[GW_APP_CON_MR_MAX_MSG_LEN];
|
|
/* cache data length */
|
|
uint16_t last_send_len;
|
|
/* 485 bus fwd data packets and takes up bus time */
|
|
uint32_t fwd_taken_time;
|
|
/* where does the message to be forwarded come from */
|
|
iot_brm_data_owner_t fwd_from;
|
|
} iot_brm_rs485_cb_t;
|
|
|
|
/* the present correcting time node inf */
|
|
typedef struct _iot_brm_correct_time_inf {
|
|
/* the present correcting time node addr */
|
|
uint8_t addr[IOT_MAC_ADDR_LEN];
|
|
/* correct time retry max retry number */
|
|
uint8_t max_num;
|
|
} iot_brm_correct_time_inf_t;
|
|
|
|
/* the connectionless correcting time information */
|
|
typedef struct _iot_brm_conn_less_cor_tm_inf {
|
|
/* count after last correct, increase by IOT_BRM_PERIOND_TIMER_INTERVAL */
|
|
uint16_t count;
|
|
/* send point, when count equal this, send message. */
|
|
uint16_t send_point;
|
|
/* correct time retry max retry number */
|
|
uint8_t retry_num;
|
|
} iot_brm_conn_less_cor_tm_inf_t;
|
|
|
|
/* branch management global descriptor */
|
|
typedef struct _iot_brm_global {
|
|
/* branch management task configuration */
|
|
iot_task_config_t task_cfg;
|
|
/* branch management task handle */
|
|
iot_task_h task_h;
|
|
/* periodic timer */
|
|
timer_id_t periodic_timer;
|
|
/* timer for node list update to nv storage */
|
|
timer_id_t node_list_timer;
|
|
/* 485 control block descriptor */
|
|
iot_brm_rs485_cb_t rs485_cb;
|
|
/* plc app regsiter configuration */
|
|
iot_plc_app_t plc_app_cfg;
|
|
/* handle of registered plc app */
|
|
iot_plc_app_h plc_app_h;
|
|
/* buffer is used to cache protocol data */
|
|
uint8_t proto_buff[PROTO_645_MAX_PKT_LEN];
|
|
/* node list structure */
|
|
iot_brm_node_list_t node_list;
|
|
/* handle of registered IPC */
|
|
iot_ipc_h ipc_h;
|
|
/* plc link state info */
|
|
iot_brm_plc_state_t plc_state;
|
|
/* branch management app global config info */
|
|
iot_brm_config_info_t cfg;
|
|
/* hanale for basic meter read */
|
|
uint32_t basic_mr_h;
|
|
/* hanale for curve pre reading task */
|
|
uint32_t lr_mr_h;
|
|
/* humidity and temperature mesurement counter, unit is 1s */
|
|
uint16_t time_cnt;
|
|
/* data forwarding id in mr buf */
|
|
uint8_t conless_cus_id;
|
|
/* flag of init external htm device fail */
|
|
uint8_t htm_invalid :1,
|
|
/* flag of get htm done */
|
|
get_htm_done :1,
|
|
/* flag to mark if power down */
|
|
pd :1,
|
|
/* flag to mark if device start up, device address is ok */
|
|
start_up :1,
|
|
/* req renew bt address flag */
|
|
set_bt_req :1,
|
|
/* is breaker */
|
|
is_brk :1,
|
|
/* reserved for future */
|
|
rsvd :2;
|
|
/* external temperature, uint is 0.1 centigrade */
|
|
int16_t ext_temperature;
|
|
/* external humidity, unit is 0.1 %RH */
|
|
int16_t ext_humidity;
|
|
/* calibrate status see - IOT_BRM_ONESHOT_CALIBRATE_XXX */
|
|
uint8_t cal_sts :2,
|
|
/* calibrate fail reason code - IOT_EM_EXT_ONESHOT_CALI_FAIL_XXX */
|
|
cal_fail_code :2,
|
|
/* reserved for future */
|
|
rsvd2 :4;
|
|
/* brm whether move dev */
|
|
uint8_t is_move_dev;
|
|
/* only proto 698.45 use sn */
|
|
uint8_t sn_proto_698;
|
|
/* seq number of 3761 message last send */
|
|
uint8_t sn_3761;
|
|
/* the present correcting time node information */
|
|
iot_brm_correct_time_inf_t cor_tm_inf;
|
|
/* onnectionless correcting time information */
|
|
iot_brm_conn_less_cor_tm_inf_t conn_less_cor_tm_inf;
|
|
/* clean mr reason timeout tm - uint: s */
|
|
uint32_t clean_mr_reason_cnt;
|
|
/* br result record buffer */
|
|
iot_brm_recv_rec_entry_t br_rec_buf;
|
|
/* br result record countdown */
|
|
uint8_t br_rec_cd;
|
|
} iot_brm_global_t;
|
|
|
|
#endif /* IOT_BRM_ENABLE && PLC_SUPPORT_STA_ROLE */
|
|
|
|