| Copyright(c) 2019 by Aerospace C.Power (Chongqing) Microelectronics. ALL RIGHTS RESERVED.
 | |
| 
 | |
| This Information is proprietary to Aerospace C.Power (Chongqing) Microelectronics and MAY NOT
 | |
| be copied by any method or incorporated into another program without
 | |
| the express written consent of Aerospace C.Power. This Information or any portion
 | |
| thereof remains the property of Aerospace C.Power. The Information contained herein
 | |
| is believed to be accurate and Aerospace C.Power assumes no responsibility or
 | |
| liability for its use in any way and conveys no license or title under
 | |
| any patent or copyright and makes no representation or warranty that this
 | |
| Information is free from patent or copyright infringement.
 | |
| 
 | |
| ****************************************************************************/
 | |
| 
 | |
| #ifndef IOT_PLC_API_H
 | |
| #define IOT_PLC_API_H
 | |
| 
 | |
| #include "os_types_api.h"
 | |
| #include "iot_plc_msg_api.h"
 | |
| #include "iot_pkt_api.h"
 | |
| 
 | |
| #ifdef __cplusplus
 | |
| extern "C" {
 | |
| #endif
 | |
| 
 | |
| /* application id range definition */
 | |
| #define IOT_PLC_APP_ID_MIN              48
 | |
| #define IOT_PLC_APP_ID_VENDOR_MIN       128
 | |
| #define IOT_PLC_APP_ID_MAX              254
 | |
| 
 | |
| /* application layer data traffic load level */
 | |
| #define IOT_PLC_APP_LOAD_LIGHT          (0)
 | |
| #define IOT_PLC_APP_LOAD_MEDIUM         (1)
 | |
| #define IOT_PLC_APP_LOAD_HEAVY          (2)
 | |
| #define IOT_PLC_APP_LOAD_MIN            IOT_PLC_APP_LOAD_LIGHT
 | |
| #define IOT_PLC_APP_LOAD_MAX            IOT_PLC_APP_LOAD_HEAVY
 | |
| #define IOT_PLC_APP_LOAD_DEFAULT        IOT_PLC_APP_LOAD_LIGHT
 | |
| 
 | |
| /* local default retry count */
 | |
| #define IOT_PLC_LOCAL_RETRY_CNT         0
 | |
| /* max retry count */
 | |
| #define IOT_PLC_MAX_RETRY_CNT           5
 | |
| /* whole network broadcast max retry count */
 | |
| #define IOT_PLC_BCAST_ALL_MAX_RETRY_CNT 3
 | |
| 
 | |
| /** \defgroup PLCLIB_APIs PLCLIB APIs
 | |
|   * @brief WQ30x1 PLCLIB APIs
 | |
|   */
 | |
| 
 | |
| 
 | |
| /** @addtogroup PLCLIB_APIs
 | |
|   * @{
 | |
|   */
 | |
| 
 | |
| /** \defgroup PLC_SHARE_APIs PLC SHARE APIs
 | |
|   * @brief Share APIs
 | |
|   *
 | |
|   * APIs can be called by CCO or STA devices
 | |
|   */
 | |
| 
 | |
| /** @addtogroup PLC_SHARE_APIs
 | |
|   * @{
 | |
|   */
 | |
| 
 | |
| /**
 | |
|  * @brief (*iot_plc_recv_func_t)() - callback to receive event from plc.
 | |
|  * @param:      parameter registered in iot_plc_register_app
 | |
|  * @param:      buffer to store the event detail, application should call
 | |
|  *              iot_free_pkt functio ASAP to free the iot pkt. it's very scarce
 | |
|  *              resource.
 | |
|  */
 | |
| typedef void (*iot_plc_recv_func_t)(void *param, iot_pkt_t *pkt);
 | |
| 
 | |
| typedef struct _iot_plc_app {
 | |
|     /** application id */
 | |
|     uint8_t             app_id;
 | |
|     /** default priority */
 | |
|     uint8_t             prio;
 | |
|     /** application load */
 | |
|     uint8_t             load;
 | |
|     /** callback to receive event from plc */
 | |
|     iot_plc_recv_func_t recv;
 | |
|     /** parameter that will be transferred back alone with the callback */
 | |
|     void                *param;
 | |
| } iot_plc_app_t;
 | |
| 
 | |
| /** plc application hanlder */
 | |
| typedef void *iot_plc_app_h;
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_register_app() - register plc application. the result will
 | |
|  *                      be notified through iot_plc_recv_func_t callback.
 | |
|  * @param app:          pointer to application descripter
 | |
|  *
 | |
|  * @return              NULL -- for failure case
 | |
|  * @return              otherwise -- plc application handler
 | |
|  */
 | |
| iot_plc_app_h iot_plc_register_app(iot_plc_app_t *app);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_calc_msdu_len_with_pad_info() - since no matter appdata len,
 | |
|  *                  the PB block size is fixed by 136 264 or 520. we reuse the
 | |
|  *                  padding bytes which transferred by MAC HW. It's
 | |
|  *                  no cost on communication bandwidth.
 | |
|  * @param app_len:      application data length.
 | |
|  * @param is_connless:  msdu send by connection or connectionless mode, cared
 | |
|  *                      by head length different.
 | |
|  * @param pad_len:      padding info len which can be reused.
 | |
|  * @return              proper msdu length needed apply for mac.
 | |
|  */
 | |
| uint16_t iot_plc_calc_msdu_len_with_pad_info(uint16_t app_len,
 | |
|     uint8_t is_connless, uint16_t *pad_len);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_alloc_msdu() - allocate iot packet for msdu data send.
 | |
|  *        data rx will be notified through iot_plc_recv_func_t callback.
 | |
|  * @param handle:       plc application handler
 | |
|  * @param msg_type:     type of the message. see IOT_PLC_MSG_TYPE_XXX
 | |
|  * @param ack_type:     required ack type. see IOT_PLC_ACK_TYPE_XXX
 | |
|  * @param dst:          final destination mac address
 | |
|  * @param src:          original source mac address
 | |
|  * @param lid:          link identifier.
 | |
|  *                          0 - 3   priority,
 | |
|  *                          4 - 254 business category,
 | |
|  *                          255     invalid. if set to 255, default
 | |
|  *                          priority registered will be used.
 | |
|  * @param len:          message length
 | |
|  * @param send_cnt:     times of sending if remote not acked,
 | |
|  *                      0 mean default times.
 | |
|  * @return              the pointer of iot packet
 | |
|  */
 | |
| iot_pkt_t *iot_plc_alloc_msdu(iot_plc_app_h handle, uint8_t msg_type,
 | |
|     uint8_t ack_type, uint8_t *dst, uint8_t *src, uint8_t lid, uint16_t len,
 | |
|     uint8_t send_cnt);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_alloc_msdu_no_encrypt() - allocate iot packet for msdu data
 | |
|  *        send. this packet can only be sent in plaintext and cannot be
 | |
|  *        encrypted, data rx will be notified through iot_plc_recv_func_t
 | |
|  *        callback.
 | |
|  * @param handle:       plc application handler
 | |
|  * @param msg_type:     type of the message. see IOT_PLC_MSG_TYPE_XXX
 | |
|  * @param ack_type:     required ack type. see IOT_PLC_ACK_TYPE_XXX
 | |
|  * @param dst:          final destination mac address
 | |
|  * @param src:          original source mac address
 | |
|  * @param lid:          link identifier.
 | |
|  *                          0 - 3   priority,
 | |
|  *                          4 - 254 business category,
 | |
|  *                          255     invalid. if set to 255, default
 | |
|  *                          priority registered will be used.
 | |
|  * @param len:          message length
 | |
|  * @param send_cnt:     times of sending if remote not acked,
 | |
|  *                      0 mean default times.
 | |
|  * @return              the pointer of iot packet
 | |
|  */
 | |
| iot_pkt_t *iot_plc_alloc_msdu_no_encrypt(iot_plc_app_h handle, uint8_t msg_type,
 | |
|     uint8_t ack_type, uint8_t *dst, uint8_t *src, uint8_t lid, uint16_t len,
 | |
|     uint8_t send_cnt);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_alloc_msdu_by_tei() - allocate iot packet for msdu data send.
 | |
|  *        data rx will be notified through iot_plc_recv_func_t callback.
 | |
|  * @param handle:       plc application handler
 | |
|  * @param msg_type:     type of the message. see IOT_PLC_MSG_TYPE_XXX
 | |
|  * @param ack_type:     required ack type. see IOT_PLC_ACK_TYPE_XXX
 | |
|  * @param dst:          final destination tei, broadcast TEI is not allowed.
 | |
|  * @param src:          original source mac address
 | |
|  * @param lid:          link identifier.
 | |
|  *                          0 - 3   priority,
 | |
|  *                          4 - 254 business category,
 | |
|  *                          255     invalid. if set to 255, default
 | |
|  *                          priority registered will be used.
 | |
|  * @param len:          message length
 | |
|  * @param send_cnt:     times of sending if remote not acked,
 | |
|  *                      0 mean default times.
 | |
|  * @return              the pointer of iot packet
 | |
|  */
 | |
| iot_pkt_t *iot_plc_alloc_msdu_by_tei(iot_plc_app_h handle, uint8_t msg_type,
 | |
|     uint8_t ack_type, uint16_t dst, uint8_t *src, uint8_t lid, uint16_t len,
 | |
|     uint8_t send_cnt);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_alloc_conn_less_msdu_ext() - allocate iot packet for
 | |
|  *        connectionless data send with specified ppm fix value.
 | |
|  *        data rx will be notified through iot_plc_recv_func_t callback.
 | |
|  * @param handle:       plc application handler
 | |
|  * @param msg_type:     type of the connectionless message.
 | |
|  *                      see IOT_PLC_MSG_TYPE_CONN_LESS_XXX
 | |
|  * @param dst:          final destination mac address
 | |
|  * @param src:          original source mac address
 | |
|  * @param lid:          link identifier.
 | |
|  *                          0 - 3   priority,
 | |
|  *                          4 - 254 business category,
 | |
|  *                          255     invalid. if set to 255, default
 | |
|  *                          priority registered will be used.
 | |
|  * @param len:          message length
 | |
|  * @param send_cnt:     times of sending if remote not acked,
 | |
|  *                      0 mean default times.
 | |
|  * @param fix_ppm:      The ppm value fixed.
 | |
|  * @param is_only_tx:   flag to mark if rx need to be switched to this ppm.
 | |
|  *                      set 0 if not required.
 | |
|  * @param tx_link_type: tx link type, see IOT_PLC_TX_LINK_TYPE_XX.
 | |
|  * @return              the pointer of iot packet
 | |
|  */
 | |
| iot_pkt_t *iot_plc_alloc_conn_less_msdu_ext(iot_plc_app_h handle,
 | |
|     uint8_t msg_type, uint8_t *dst, uint8_t *src, uint8_t lid, uint16_t len,
 | |
|     uint8_t send_cnt, int8_t fix_ppm, uint8_t is_only_tx, uint8_t tx_link_type);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_alloc_conn_less_msdu() - allocate iot packet for
 | |
|  *        connectionless data send. data rx will be notified through
 | |
|  *        iot_plc_recv_func_t callback.
 | |
|  * @param handle:       plc application handler
 | |
|  * @param msg_type:     type of the connectionless message.
 | |
|  *                      see IOT_PLC_MSG_TYPE_CONN_LESS_XXX
 | |
|  * @param dst:          final destination mac address
 | |
|  * @param src:          original source mac address
 | |
|  * @param lid:          link identifier.
 | |
|  *                          0 - 3   priority,
 | |
|  *                          4 - 254 business category,
 | |
|  *                          255     invalid. if set to 255, default
 | |
|  *                          priority registered will be used.
 | |
|  * @param len:          message length
 | |
|  * @param send_cnt:     times of sending if remote not acked,
 | |
|  *                      0 mean default times.
 | |
|  * @return              the pointer of iot packet
 | |
|  */
 | |
| #define  iot_plc_alloc_conn_less_msdu(handle, msg_type, dst, src, lid, len, \
 | |
|     send_cnt) iot_plc_alloc_conn_less_msdu_ext(handle, msg_type, \
 | |
|     dst, src, lid, len, send_cnt, 0, 0, IOT_PLC_TX_LINK_TYPE_HPLC)
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_rf_alloc_conn_less_msdu() - allocate rf iot packet for
 | |
|  *        connectionless data send. data rx will be notified through
 | |
|  *        iot_plc_recv_func_t callback.
 | |
|  * @param handle:       plc application handler
 | |
|  * @param msg_type:     type of the connectionless message.
 | |
|  *                      see IOT_PLC_MSG_TYPE_CONN_LESS_XXX
 | |
|  * @param dst:          final destination mac address
 | |
|  * @param src:          original source mac address
 | |
|  * @param lid:          link identifier.
 | |
|  *                          0 - 3   priority,
 | |
|  *                          4 - 254 business category,
 | |
|  *                          255     invalid. if set to 255, default
 | |
|  *                          priority registered will be used.
 | |
|  * @param len:          message length
 | |
|  * @param send_cnt:     times of sending if remote not acked,
 | |
|  *                      0 mean default times.
 | |
|  * @return              the pointer of iot packet
 | |
|  */
 | |
| #define  iot_plc_rf_alloc_conn_less_msdu(handle, msg_type, dst, src, lid, len, \
 | |
|     send_cnt) iot_plc_alloc_conn_less_msdu_ext(handle, msg_type, \
 | |
|     dst, src, lid, len, send_cnt, 0, 0, IOT_PLC_TX_LINK_TYPE_RF)
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_alloc_ctrl_proto_msdu() - allocate iot packet for Controller
 | |
|  *        protocol data send. data rx will be notified through
 | |
|  *        iot_plc_recv_func_t callback.
 | |
|  * @param handle:       plc application handler
 | |
|  * @param dst:          final destination mac address
 | |
|  * @param src:          original source mac address
 | |
|  * @param lid:          link identifier.
 | |
|  *                          0 - 3   priority,
 | |
|  *                          4 - 254 business category,
 | |
|  *                          255     invalid. if set to 255, default
 | |
|  *                          priority registered will be used.
 | |
|  * @param len:          message length
 | |
|  * @param send_cnt:     times of sending if remote not acked,
 | |
|  *                      0 mean default times.
 | |
|  * @return              the pointer of iot packet
 | |
|  */
 | |
| iot_pkt_t *iot_plc_alloc_ctrl_proto_msdu(iot_plc_app_h handle,
 | |
|     uint8_t *dst, uint8_t *src, uint8_t lid, uint16_t len, uint8_t send_cnt);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_send_msdu() - send a packet through the plc. there is no
 | |
|  *                      guarantee that the packet will be delivered to the
 | |
|  *                      final destination as the plc network is unreliable. the
 | |
|  *                      pkt must be allocated through iot_plc_alloc_msdu api.
 | |
|  * @param handle:       plc application handler
 | |
|  * @param pkt:          pointer to the packet
 | |
|  */
 | |
| void iot_plc_send_msdu(iot_plc_app_h handle, iot_pkt_t *pkt);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_query_dev_info() - get info of local device
 | |
|  * @param handle:       plc application handler
 | |
|  * @param req_id:       request id, the request id will be transferred back to
 | |
|  *                      app in the report. app can define the mean of each id
 | |
|  *                      itself.
 | |
|  */
 | |
| void iot_plc_query_dev_info(iot_plc_app_h handle, uint8_t req_id);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_query_nid() - get nid of the current network, a
 | |
|  *                      iot_plc_dev_info_rpt message will be replied
 | |
|  * @param handle:       plc application handler
 | |
|  * @param req_id:       request id, the request id will be transferred back to
 | |
|  *                      app in the report. app can define the mean of each id
 | |
|  *                      itself.
 | |
|  */
 | |
| void iot_plc_query_nid(iot_plc_app_h handle, uint8_t req_id);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_query_nb_nw_info() - get info of neighbour network
 | |
|  *                      a iot_plc_nb_nw_info_t message will be replied
 | |
|  * @param handle:       plc application handler
 | |
|  * @param req_id:       request id, the request id will be transferred back to
 | |
|  *                      app in the report. app can define the mean of each id
 | |
|  *                      itself.
 | |
|  */
 | |
| void iot_plc_query_nb_nw_info(iot_plc_app_h handle, uint8_t req_id);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_query_whitelist() - query whitelist
 | |
|  * @param start:            start index of whitelist entry
 | |
|  * @param req_id:           request id, the request id will be transferred back
 | |
|  *                          to app in the report. app can define the mean of
 | |
|  *                          each id itself.
 | |
|  * @param cnt:              count of entries to retrieve
 | |
|  */
 | |
| void iot_plc_query_whitelist(iot_plc_app_h handle, uint8_t req_id,
 | |
|     uint16_t start,uint16_t cnt);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_query_blacklist() - query blacklist
 | |
|  * @param start:            start index of blacklist entry
 | |
|  * @param req_id:           request id, the request id will be transferred back
 | |
|  *                          to app in the report. app can define the mean of
 | |
|  *                          each id itself.
 | |
|  * @param cnt:              count of entries to retrieve
 | |
|  */
 | |
| void iot_plc_query_blacklist(iot_plc_app_h handle, uint8_t req_id,
 | |
|     uint16_t start, uint16_t cnt);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_set_whitelist() - set whitelist
 | |
|  * @param handle:           plc application handler
 | |
|  * @param req_id:           request id, the request id will be transferred back
 | |
|  *                          to app in the report. app can define the mean of
 | |
|  *                          each id itself.
 | |
|  * @param action:           action of whitelist operation. available
 | |
|  *                          value is IOT_PLC_WL_XXX
 | |
|  * @param count:            number of mac address
 | |
|  * @param mac_addry_array:  array of mac address, big endian
 | |
|  */
 | |
| void iot_plc_set_whitelist(iot_plc_app_h handle, uint8_t req_id, uint8_t action,
 | |
|     uint16_t count, uint8_t *mac_addr_array);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_set_whitelist_ex() - set whitelist
 | |
|  * @param handle:           plc application handler
 | |
|  * @param req_id:           request id, the request id will be transferred back
 | |
|  *                          to app in the report. app can define the mean of
 | |
|  *                          each id itself.
 | |
|  * @param action:           action of whitelist operation. available
 | |
|  *                          value is IOT_PLC_WL_XXX
 | |
|  * @param count:            number of mac address
 | |
|  * @param mac_addry:        array of mac address
 | |
|  * @param big:              flag to mark if the mac address is big endian
 | |
|  *                          in the array
 | |
|  */
 | |
| void iot_plc_set_whitelist_ex(iot_plc_app_h handle, uint8_t req_id,
 | |
|     uint8_t action, uint16_t count, uint8_t *mac_addr, uint8_t big);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_set_blacklist() - set blacklist
 | |
|  * @param handle:           plc application handler
 | |
|  * @param req_id:           request id, the request id will be transferred back
 | |
|  *                          to app in the report. app can define the mean of
 | |
|  *                          each id itself.
 | |
|  * @param action:           action of blacklist operation. available
 | |
|  *                          value is IOT_PLC_WL_XXX
 | |
|  * @param count:            number of mac address
 | |
|  * @param mac_addry_array:  array of mac address
 | |
|  */
 | |
| void iot_plc_set_blacklist(iot_plc_app_h handle, uint8_t req_id, uint8_t action,
 | |
|     uint16_t count, uint8_t * mac_addr_array);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_set_cfg() - set configuration of local device
 | |
|  * @param handle:       plc application handler
 | |
|  * @param req_id:       request id, the request id will be transferred back to
 | |
|  *                      app in the report. app can define the mean of each id
 | |
|  *                      itself.
 | |
|  * @param cfg:          pointer to detail configuration
 | |
|  */
 | |
| void iot_plc_set_cfg(iot_plc_app_h handle, uint8_t req_id,
 | |
|     iot_plc_cfg_set_req_t *cfg);
 | |
| 
 | |
| /**
 | |
|  * @brief   iot_plc_set_freq_band() - set carrier communication frequency band.
 | |
|  *          if local device is CCO, the band id info will be saved and applied
 | |
|  *          after each restart.
 | |
|  *          if local device is STA, the request is only accepted when STA is
 | |
|  *          not associated with any network. in addition, the band id info will
 | |
|  *          be lost after each restart or associated with a network.
 | |
|  *
 | |
|  * @param   handle:    plc application handler
 | |
|  * @param   req_id:    request id, the request id will be transferred back to
 | |
|  *                     app in the report. app can define the mean of each id
 | |
|  *                     itself.
 | |
|  * @param   freq_band: see PLC_LIB_FREQ_BAND_xxx
 | |
|  */
 | |
| void iot_plc_set_freq_band(iot_plc_app_h handle, uint8_t req_id,
 | |
|     uint8_t freq_band);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_set_rf_channel() - plc set rf channel.
 | |
|  *
 | |
|  * @param handle:       plc application handler
 | |
|  * @param req_id:       request id, the request id will be transferred back to
 | |
|  *                      app in the report. app can define the mean of each id
 | |
|  *                      itself.
 | |
|  * @param option:       rf option, see IOT_PLC_RF_OPTION_XXX.
 | |
|  * @param channel:      rf channel, see IOT_PLC_CHANNEL_ID_XXX.
 | |
|  * @param rf_cod_enable: flag to mark if enable rf channel coordination,
 | |
|  *                       0 - disable, 1 - enable, it only valid for CCO device.
 | |
|  */
 | |
| void iot_plc_set_rf_channel(iot_plc_app_h handle, uint8_t req_id,
 | |
|     uint8_t option, uint8_t channel, uint8_t rf_cod_enable);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_start_nw_fmt() - start network formation
 | |
|  * @param handle:       plc application handler
 | |
|  * @param force:        flag to mark if force start required. if plc network
 | |
|  *                      formation already started, set this flag will restart
 | |
|  *                      the whole process from the very beginning.
 | |
|  */
 | |
| void iot_plc_start_nw_fmt(iot_plc_app_h handle, uint8_t force);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_stop_nw_fmt() - stop network formation
 | |
|  * @param handle:       plc application handler
 | |
|  */
 | |
| void iot_plc_stop_nw_fmt(iot_plc_app_h handle);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_query_band_info() - query carrier communication frequency band
 | |
|  *
 | |
|  * @param  handle:     plc application handler
 | |
|  * @param  req_id:     request id, the request id will be transferred back to
 | |
|  *                     app in the report. app can define the mean of each id
 | |
|  *                     itself.
 | |
|  */
 | |
| void iot_plc_query_band_info(iot_plc_app_h handle, uint8_t req_id);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_query_neighbor_by_mac() - query the founded neighbor devices in
 | |
|  *        the same network by mac. the result will be notified through
 | |
|  *        iot_plc_recv_func_t callback.
 | |
|  * @param handle:       plc application handler
 | |
|  * @param req_id:       request id, the request id will be transferred back to
 | |
|  *                      app in the report. app can define the mean of each id
 | |
|  *                      itself.
 | |
|  * @param node_mac:     the node mac array to be queried, big endian
 | |
|  * @param node_cnt:     count of nodes to be queried
 | |
|  */
 | |
| void iot_plc_query_neighbor_by_mac(iot_plc_app_h handle,
 | |
|     uint8_t req_id, uint8_t *node_mac, uint8_t node_cnt);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_query_neighbor_dev() - query the founded neighbor devices in
 | |
|  *        the same network. the result will be notified through
 | |
|  *        iot_plc_recv_func_t callback.
 | |
|  * @param handle:       plc application handler
 | |
|  * @param req_id:       request id, the request id will be transferred back to
 | |
|  *                      app in the report. app can define the mean of each id
 | |
|  *                      itself.
 | |
|  * @param start:        start tei of the query
 | |
|  * @param cnt:          requested number of valid entries
 | |
|  * @param start_type:   start type, see IOT_PLC_QUERY_TOPO_START_AS_XXX
 | |
|  */
 | |
| void iot_plc_query_neighbor_dev(iot_plc_app_h handle, uint8_t req_id,
 | |
|     uint16_t start, uint16_t cnt, uint8_t start_type);
 | |
| 
 | |
| /**
 | |
|  * @brief   iot_plc_query_tei_addr_info() - query tei address information
 | |
|  * @param   handle:     plc application handler
 | |
|  * @param   req_id:     request id, the request id will be transferred back to
 | |
|  *                      app in the report. app can define the mean of each id
 | |
|  *                      itself.
 | |
|  * @param   start_tei:  start tei
 | |
|  * @param   offset:     start query position. bit0 = 0, bit1 = 1, bit2 = 2, ...
 | |
|  * @param   bm_len:     bm len
 | |
|  * @param   bm:         tei bitmap used for query tei addr,
 | |
|  *                      bit0 represent start tei,
 | |
|  *                      bit1 represent start tei + 1 and so on
 | |
|  */
 | |
| void iot_plc_query_tei_addr_info(iot_plc_app_h handle, uint8_t req_id,
 | |
|     uint16_t start_tei, uint16_t offset, uint8_t bm_len, uint8_t *bm);
 | |
| 
 | |
| /**
 | |
|  * @brief   iot_plc_set_tx_power_cap() - set carrier communication tx power cap
 | |
|  * @param   handle: plc application handler
 | |
|  * @param   req_id: request id, the request id will be transferred back to app
 | |
|  *                  in the report. app can define the mean of each id itself.
 | |
|  * @param   hplc_power:  pointer to hplc tx power cap. unit is 1 dbuv,
 | |
|  *                       range 95 - 137, see IOT_PLC_HPLC_TX_POWER_XXX.
 | |
|  * @param   rf_power:    pointer to rf tx power cap. unit is 1 dbm,
 | |
|  *                       range -35 - 20, see IOT_PLC_RF_TX_POWER_XXX.
 | |
|  * @return:
 | |
|  *  ERR_OK      -- for success case
 | |
|  *  otherwise   -- error code
 | |
|  */
 | |
| uint32_t iot_plc_set_tx_power_cap(iot_plc_app_h handle, uint8_t req_id,
 | |
|     uint8_t *hplc_power, int8_t *rf_power);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_tsfm_state_change() - change the state of transformer detect.
 | |
|  *
 | |
|  * @param handle:   plc application handler.
 | |
|  * @param req_id:   request id, the request id will be transferred back to app
 | |
|  *                  in the report. app can define the mean of each id itself.
 | |
|  * @param status:   the status of transformer detect, see
 | |
|  *                  IOT_PLC_TSFM_STATE_XXX.
 | |
|  * @param tsfm_addr:    transformer mac address. only used in
 | |
|  *                      IOT_PLC_TSFM_STATE_LOCK case.
 | |
|  * @param wl_notify_enable: flag to mark if white list notification enable,
 | |
|  *                  invalid for sta role case. 0 - disable, 1 - enable.
 | |
|  * @param zc_notify_enable: flag to mark if zc ntb notification enable,
 | |
|  *                          invalid for sta role case. 1 - broadcast, 0 - not.
 | |
|  * @param net_lock_time: pointer to the net lock time, NULL mean that the net
 | |
|  *                  lock time is invalid.
 | |
|  * @param abn_lock_time: pointer to the lock time of abnormal leave net, NULL
 | |
|  *                  mean that the lock time of abnormal leave net is invalid.
 | |
|  * @param unlock_delay: network unlock delay time, unit is 1min.
 | |
|  */
 | |
| void iot_plc_tsfm_state_change(iot_plc_app_h handle, uint8_t req_id,
 | |
|     uint8_t status, uint8_t *tsfm_addr, uint8_t wl_notify_enable,
 | |
|     uint8_t zc_notify_enable, uint16_t *net_lock_time, uint16_t *abn_lock_time,
 | |
|     uint16_t unlock_delay);
 | |
| 
 | |
| /**
 | |
|  * @brief   get NTB value of local device. note that, if network
 | |
|  *          formation is not done, this value is not reliable.
 | |
|  *
 | |
|  * @param handle:   plc application handler.
 | |
|  */
 | |
| uint32_t iot_plc_get_ntb(iot_plc_app_h handle);
 | |
| 
 | |
| /**
 | |
|  * @brief   enable/disable watch dog function in PLC. by default, if plc
 | |
|  *          network formation can't be done within 30 min, system restart
 | |
|  *          will be triggered.
 | |
|  *
 | |
|  * @param handle:   plc application handler.
 | |
|  * @param enable:   1 to enable. 0 to disable.
 | |
|  * @param interval: watch dog bite interval, unit is 1 min, less than 30
 | |
|  *                  minutes is disallowed.
 | |
|  */
 | |
| void iot_plc_wdg_set(iot_plc_app_h handle, uint8_t enable, uint16_t interval);
 | |
| 
 | |
| /**
 | |
|  * @brief:  get if device is running in sta or cco role
 | |
|  *
 | |
|  * @retval: return true if device is running in sta role.
 | |
|  */
 | |
| bool_t iot_plc_is_client_mode();
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_query_local_phase() - query phase information of local device.
 | |
|  *
 | |
|  * @param handle:    plc application handler
 | |
|  * @param req_id:    request id, the request id will be transferred back to
 | |
|  *                   app in the report. app can define the mean of each id
 | |
|  *                   itself.
 | |
|  */
 | |
| void iot_plc_query_local_phase(iot_plc_app_h handle, uint8_t req_id);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_zc_collect() - collect zero-crossing information of
 | |
|  *                   local device.
 | |
|  *
 | |
|  * @param handle:    plc application handler
 | |
|  * @param req_id:    request id, the request id will be transferred back to
 | |
|  *                   app in the report. app can define the mean of each id
 | |
|  *                   itself.
 | |
|  * @param start_ntb: time to start collecting, unit is 1 ntb. the actual number
 | |
|  *                   of collection may be less than the required number, because
 | |
|  *                   there is not enough data at the current time, so caller
 | |
|  *                   need to delay the request for a while, caller can delay
 | |
|  *                   1-5s based on the amount of data and then request again.
 | |
|  * @param cnt:       collection count, if the local device has 3 phase zc data,
 | |
|  *                   and collecton count is not a multiple of 3, the count of
 | |
|  *                   actual collection returned is a multiple of 3.
 | |
|  */
 | |
| void iot_plc_zc_collect(iot_plc_app_h handle, uint8_t req_id,
 | |
|     uint32_t start_ntb, uint8_t cnt);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_query_band_bitmap() - plc query band bitmap.
 | |
|  *
 | |
|  * @param handle:       plc application handler
 | |
|  * @param req_id:       request id, the request id will be transferred back to
 | |
|  *                      app in the report. app can define the mean of each id
 | |
|  *                      itself.
 | |
|  * @param is_scan_band: 0: scan band bitmap; 1: support band bitmap.
 | |
|  */
 | |
| void iot_plc_query_band_bitmap(iot_plc_app_h handle, uint8_t req_id,
 | |
|     uint8_t is_scan_band);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_set_rate_adapt_mode() - set tx adapt mode
 | |
|  *
 | |
|  * @param handle:       plc application handler
 | |
|  * @param req_id:       request id, the request id will be transferred back to
 | |
|  *                      app in the report. app can define the mean of each id
 | |
|  *                      itself.
 | |
|  * @param target_node:      see IOT_PLC_RATE_ADAPT_NODE_XXX
 | |
|  * @param rate_adapt_mode:  see IOT_PLC_RATE_ADAPT_MODE_XXX
 | |
|  * @param fixed_rate_level: see IOT_PLC_RATE_ADAPT_RATE_XXX, this value is valid
 | |
|  *                      only when target_node == IOT_PLC_RATE_ADAPT_NODE_LOCAL
 | |
|  *                      and rate_adapt_mode == IOT_PLC_RATE_ADAPT_MODE_FIX.
 | |
|  *                      note that the higher the rate, the weaker the
 | |
|  *                      anti-attenuation ability.
 | |
|  * @return:             none
 | |
|  */
 | |
| void iot_plc_set_rate_adapt_mode(iot_plc_app_h handle, uint8_t req_id,
 | |
|     uint8_t target_node, uint8_t rate_adapt_mode, uint8_t fixed_rate_level);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_set_authrz_dak() - set authorized DAK/MAC pair info
 | |
|  *
 | |
|  * @param handle:       plc application handler
 | |
|  * @param req_id:       request id, the request id will be transferred back to
 | |
|  *                      app in the report. app can define the mean of each id
 | |
|  *                      itself.
 | |
|  * @param dak:          DAK/MAC pair info
 | |
|  */
 | |
| void iot_plc_set_authrz_dak(iot_plc_app_h handle, uint8_t req_id,
 | |
|     iot_plc_authrz_dak_set_req_t *dak);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_get_link_load() - get hplc link traffic load
 | |
|  * @return:    percentage value: 0 - 100. 0 means light, 100 means heavy.
 | |
|  */
 | |
| uint8_t iot_plc_get_link_load();
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_get_link_statistics() - get plc link statistics
 | |
|  * @param stat: return plc link statistics
 | |
|  */
 | |
| void iot_plc_get_link_statistics(iot_plc_link_statistics_t *stat);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_set_rf_scan_tbl() - plc set rf scan table.
 | |
|  *
 | |
|  * @param handle:       plc application handler
 | |
|  * @param req_id:       request id, the request id will be transferred back to
 | |
|  *                      app in the report. app can define the mean of each id
 | |
|  *                      itself.
 | |
|  * @param rf_scan_tbl:  pointer to rf scan table.
 | |
|  * @param rf_cnt:       count of valid rf entry in rf scan table, and no more
 | |
|  *                      than IOT_PLC_RF_SCAN_TBL_MAX.
 | |
|  */
 | |
| void iot_plc_set_rf_scan_tbl(iot_plc_app_h handle, uint8_t req_id,
 | |
|     iot_plc_rf_scan_t *rf_scan_tbl, uint8_t rf_cnt);
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_get_comm_type() - get plc communication type
 | |
|  * @return:    IOT_PLC_COMM_TYPE_XXX
 | |
|  */
 | |
| uint8_t iot_plc_get_comm_type();
 | |
| 
 | |
| /**
 | |
|  * @brief iot_plc_get_local_nf() - get local noise floor.
 | |
|  * @return:  unit is dBuV, valid value is 20 ~ 117.
 | |
|  */
 | |
| uint8_t iot_plc_get_local_nf();
 | |
| #ifdef __cplusplus
 | |
| }
 | |
| #endif
 | |
| 
 | |
| #endif /* IOT_PLC_API_H */
 |